PRODUCTS
 
  Solution Alarm Panels
 Solution 64 / Solution 16 Plus
GRAPHIC USER INTERFACE TECHNOLOGY
 
Featured on Bosch Solution 64 and Solution 16plus, Bosch Graphic User Interface Technology delivers the most comprehensive displays available! The large back lit LCD display uses pixel technology from Bosch to graphically display all system conditions at a glance. Programmable features and options are displayed using simple text menus, allowing the system to be programmed and configured, practically without referring to the manual. At all times the user and installer are prompted in plain English text, clearly identifying the current operating mode and enhancing feedback for trouble free and simple operation.

An enhanced version of the Graphic Code Pad incorporates a built-in proximity reader allowing users to simply present their token to the Code Pad to arm/disarm and or unlock a door. Children and the elderly will find this feature extremely easy to use as no PIN codes are required for operation. A maximum of 8 Code Pads in any combination (proximity enabled or not) are available per system. Solution 64 and Solution 16plus panels may be fully programmed using the graphic interface or using a PC loaded with Solution Link software. Built on SQL database technology, the Windows based Solution Link software offers single and multi-user operation, with the ability to control the functions each operator can perform via programmable authority levels.
 Graphic User Interface with optional Proximity Reader built-in
 Full Menu Text Programming
 Free Text for users, zones, outputs, areas & schedules
 Digital Contrast and Brightness Control
 Attractive Modern Slimline Design
 Temperature Display
 Dedicated On, Off and Part Keys
 Simple to arm & disarm. PIN + ON or OFF
 Code Pad Hold down functions, Duress, Panic and Fire
 On/Off status LEDs
 Delayed trouble beeps
 
PART NUMBER DESCRIPTION PRICE EX GST
 
CC110X  
Solution 64 Control Panel (with transformer)

 Graphic User Interface with optional Proximity Reader built-in
 Integrated Access Control
 Multi-Vendor Wireless Compatible
 Programmable EOL Resistor Values
 Sensor Watch
 Telco Line Fail Detection
 Dual Reporting
 C.L.I. Enabled Intelli-Connect
 CID, SIA, Domestic, Voice, SMS Reports
 16 On-Board zones expandable to 64 wired or wireless
 128 Users
 Partitionable to 8 areas
 3 year warranty
CC110P  
Solution 64 Control Panel (PCB Only)
CC110TW  
Solution 64 Control Panel with Plug Pack
CC100X  
Solution 16PLUS Control Panel (with transformer)

 Graphic User Interface with optional Proximity Reader built-in
 Multi-Vendor Wireless Compatible
 Programmable EOL Resistor Values
 Sensor Watch
 Telco Line Fail Detection
 Dual Reporting
 C.L.I. Enabled Intelli-Connect
 CID, SIA, Domestic, Voice, SMS Reports
 16 On-Board zones wired or wireless
 48 Users
 Partitionable to 4
CC100P  
Solution 16PLUS Control Panel (PCB Only)
CC100TW  
Solution 16PLUS Control Panel with Plug Pack
Code Pads
 
CP100W  
Solution 64/16PLUS Graphic Code Pad
White with Green LCD screen

 Graphic LCD Display
 Slim Line Design
 Large backlit Code pad keys
 Dedicated On, Off and Part Mode keys
 Choice of White with Green LCD or Black with Blue LCD
 Digital Contrast and Brightness Control
 Code Pad Hold down functions, Duress, Panic and Fire
 On/Off status LEDs
 Delayed trouble beeps
 Optional Built in Proximity Reader
 Remote Arming, Disarming & Area Control
 Chime Alarm
CP110B  
Black with Blue LCD screen
CP101W  
White with Green LCD screen & Built-in Proximity Reader
CP111B  
Black with Blue LCD screen & Built-in Proximity Reader
Solution 64/16Plus Modules
 
CM104  
8/16 Zone Expander PCB Only

8 / 16 zones expansion
Dip switch addressable
Automatic recognition and configuration by control panel
Fully monitored by control panel
Separate tamper input
Status LED
CM105  
16/32 Zone Expander with Enclosure

16 / 32 zones expansion
Dip switch addressable
Compatible with CM106 8 / 16 zone piggy back expander
Automatic recognition and configuration by control panel
Fully monitored by control panel
Separate tamper input
Status LED
Powered by panel bus or external power
CM105P  
16/32 Zone Expander PCB Only
CM106  
8/16 Zone Piggy back Expander

8 / 16 zones expansion
Connects to CM105 allowing expansion up to 32 zones
CM110  
4 Way Relay Module with 2 External Proximity Inputs

4 x 2A Form C relay outputs
2 x Proximity Reader Inputs
Automatic recognition and configuration by control panel
Fully monitored by control panel
Separate tamper input
CM120  
1AMP Power Supply & Battery Charger

2 x 500mA 13.8VDC outputs
Separate PTC fused protection per output
On-board battery Charge circuit
Mains, Power Supply status and Low Battery LEDs
Output power LEDs
AC fail output
Dip switch addressable
Automatic recognition and configuration by control panel
Fully monitored by control panel
Separate tamper input
CM195  
1AMP Power Supply & Battery Charger

Allows up to 3 RF receivers to be simultaneously connected to control panel
Allows connection of 3rd party wireless systems
Separate Status LED for each receiver connected to CM195 Dip
switch addressable
Automatic recognition and configuration by control panel
Fully monitored by control panel
Separate tamper input
Readers & Tokens
 
PR100  
DF Weatherproof External RFID Reader 5cm
PR200  
RFID Proximity Token - Grey (Pack of 10)
PR201  
RFID Proximity Token - Black Keyring (Pack of 10)
PR250  
RFID Prox ISO Card - White (Pack of 10)
PR260  
RFID Prox Card - Clam Shell with Cut out (Pack of 10)
Enclosures
 
 
 
 
Software & Accessories
 
SW500  
SolutionLink Upload / Download Software
 
 
 
 

 Solution 16i
TEXT ICON USER INTERFACE TECHNOLOGY
 
Using fixed text and easy-to-recognise icons, the Solution 16i code pad takes proven Bosch LCD icon technology to a new level. System status can be determined at a glance during operation, with menu locations and parameter information clearly displayed during programming. No longer are technicians left to determine parameters by interpretation of icons. No longer will you be left wondering exactly which memory location you are looking at.

An enhanced version of the Solution 16i code pad incorporates a built-in proximity reader allowing users to simply present their token to the code pad to arm / disarm the system and / or unlock a door. Children and the elderly will find this feature extremely easy to use as no pin is required for normal operation.

You can program the Solution 16i via the code pad or using a PC loaded with Solution Link software. Built on SQL database technology, the Windows based Solution Link software offers single and multi-user operation, with the ability to control the functions each operator can perform via programmable authority levels.
 Graphic User Interface with optional Proximity Reader built-in
 Full Menu Text Programming
 Free Text for users, zones, outputs, areas & schedules
 Digital Contrast and Brightness Control
 Attractive Modern Slimline Design
 Temperature Display
 Dedicated On, Off and Part Keys
 Simple to arm & disarm. PIN + ON or OFF
 Code Pad Hold down functions, Duress, Panic and Fire
 On/Off status LEDs
 Delayed trouble beeps
 
PART NUMBER DESCRIPTION PRICE EX GST
 
CC500X  
Solution 16i Control Panel (with transformer)

 Text ICON LCD Display with optional proximity reader
 Multi-Vendor Wireless Compatible
 Programmable EOL Resistor Values
 Sensor Watch
 Telco Line Fail Detection
 Dual Reporting
 Caller ID enabled for remote connect
 CID, SIA, Domestic, Voice, SMS Reports
 16 On-Board zones wired or wireless
 48 Users
 Partitionable to 4 areas
 Fully Programmable from the Code Pad
 Programmable via SolutionlinkTM Software (Remote/Direct)
 3 year warranty
 Use with CP510i & CP511i code pads only
CC500P  
Solution 16i Control Panel (PCB Only)
CC500TW  
Solution 16i Control Panel with Plug Pack
Code Pads
 
 
CP510i  
Solution 16ICON Code Pad

 Text ICON LCD Display
 Slim Line Design
 Large backlit Code pad keys
 Dedicated On, Off and Part Mode keys
 Digital Contrast and Brightness Control
 Code Pad Hold down functions, Duress, Panic and Fire
 On/Off status LEDs
 Delayed trouble beeps
 Optional Built in Proximity Reader
 Remote Arming, Disarming & Area Control
 Chime Alarm
CP511i  
With Built-in Proximity Reader
 
Night Arm Station

Designed for placement by the bedside, the CP050 allows you to arm your system in the PART mode 1 or PART mode 2 by pressing one button, and to disarm your system (provided no alarms have occurred). It also allows you to trigger a panic alarm at any time of the day or night should an emergency situation arise.
Solution 16i Modules
 
CM704B  
8/16 Zone expansion module

• Provides 8 physical zone input terminations per module
• Allows zones to be remotely located away from control panel to reduce cabling costs
• Supports both LAN or external power
• Separate tamper input
• Service code pad input
CM710B  
4 Way Relay Output Module

• 4 x Form C relays
• 2 Amp contact rating at 24VDC
• May be remotely located and controlled from panel
• Separate tamper input
• Service code pad input
CM195  
Multi RF Receiver Interface

• 3 x independent wireless receiver inputs
• Support for multiple vendors RF technologies
• Allows increased wireless coverage and reliability
• Easy 3 wire connection to the control panel
• Data received and processed indicators
Readers & Tokens
 
PR200  
RFID Proximity Token - Grey (Pack of 10)
PR201  
RFID Proximity Token - Black Keyring (Pack of 10)
PR250  
RFID Prox ISO Card - White (Pack of 10)
PR260  
RFID Prox Card - Clam Shell with Cut out (Pack of 10)
Enclosures
 
 
 
 
Software & Accessories
 
 
 
 
 
 

 Solution 16
The Solution 16 control panel provides sixteen programmable hard wired zones across. Remote programming using Alarm link software provides added convenience and capability. With four areas and three arming modes the Solution 16 control panel is a flexible system ideal for domestic and small commercial installations. The system supports up to 32 users.

For the installer the Solution 16 provides a robust trouble free platform to ensure quality installations, with a choice of different EOL resistor values allowing the control panel to be easily retrofitted into an existing installation.

Post installation the Solution 16 sensor watch feature monitors the activity of the devices connected to the control panel, ensuring devices remain serviceable and that system integrity is maintained.
 
PART NUMBER DESCRIPTION PRICE EX GST
 
CC880X  
Solution 16 Control Panel (with transformer)

 16 zone control panel
 16 fully programmable zones
 Expandable to 16 outputs
 32 User codes
 Partitionable to 4 areas
 Domestic dialling
 Selectable EOL
 Automatic arm
 Day alarm
 Perfect for medium to large residential applications and retail outlets
 Use with CP516LW or CP516W code pads . When partitioned use with CP500PW or CP500AW code pads.
CC880P  
Solution 16 Control Panel (PCB Only)
CC880TW  
Solution 16 Control Panel with Plug Pack
Code Pads
 
CP516LW  
ICON 16 zone code pad suitable for all Solution 16 panels
 
CP500ALW  
ICON 8 zone addressable code pad
to suit Solution 880 series and Solution 16 when partitioning
CP516W  
16 zone LED code pad
suitable for all Solution 16 panels
CP500AW  
Addressable code pad
to suit Solution 880 series and Solution 16 when partitioning
 
CP500PW  
Master Partitionable code pad
for viewing status of all areas on Solution 880 series and Solution 16 when partitioned
 
CP105A  
Night Arm Station

Designed for placement by the bedside, the CP105A allows you to arm your system in the STAY mode by pressing one button and also disarm your system provided no alarms have occurred. It also allows you to trigger a panic alarm at any time of the day or night should an emergency situation arise.
 
Solution 16 Modules
 
 
 
Modem Module
for Solution 844, 880 Ultima and Solution 16 Control panels
for SMS reporting, as applicable
 
 
Telephone DTMF Command Module

• Telephone DTMF Command Module
• Allows you to call from any touch tone phone in the world and program, arm and disarm the Control Panel
• It will also allow domestic dialling to be acknowledged & remote outputs to be switched on / off via the phone.
 
 
Voice Module

• Programmable Voice Recorder Module for Domestic Voice Reporting
• Maximum 16 second message that can be changed as often as required with 10 year memory retention
• No need to reprogram after loss of power
• No batteries required
 
 
Solution Line Fault Module

• Telephone Line Fault Monitor Module monitors the phone line and provides an output and / or triggers the siren when the line fails or is disconnected from the system
 
 
Solution 16 & 800 Programming Key
Allows you to store your standard programming options and then to program other panels with those options in 5 seconds
Enclosures
 
 
Software & Accessories
 
 
 
 

 Solution 880 Ultima
Solution 880 Ultima
The Solution 880 Ultima control panel provides eight programmable hard-wired or wireless zones. The Solution 880 control panel provides eight wired only zones. Remote programming using Alarm link software provides added convenience and capability.

With two areas and three arming modes the Ultima control panel is a flexible system ideal for domestic and small commercial installations.

For the installer these panels provide a robust trouble free platform to ensure quality installations, with a choice of different EOL resistor values allowing the control panel to be easily retrofitted into an existing installation.

Post installation, the Solution 880 Series sensor watch feature monitors the activity of the devices connected to the control panel, ensuring devices remain serviceable and that system integrity is maintained.

The Solution 880 Ultima is compatible with Bosch Wireless (DSRF) technology.
 
PART NUMBER DESCRIPTION PRICE EX GST
 
CC488X  
Solution Ultima 880 Control Panel with transformer

• 8 zone control panel
• 8 fully programmable zones
• Wireless capable (with RF3212E)
• 16 wireless devices
• 8 User codes
• Dual reporting
• Partitionable to 2 areas
• Domestic dialling
• Selectable EOL
• Automatic arm / disarm
• Day alarm
• Perfect for small to medium residential applications and small retail outlets
• Use with CP508LW or CP508W code pads
CC488P  
Solution Ultima 880 Control Panel (PCB Only)
CC488TW  
Solution Ultima 880 Control Panel with Plug Pack
Code Pads
 
CP508LW  
8 Zone LCD Code Pad
 
CP500ALW  
ICON 8 zone addressable code pad
to suit Solution 880 series and Solution 16 when partitioning
CP508W  
8 Zone LED Code Pad
suitable for all Solution 16 panels
CP500AW  
Addressable code pad
to suit Solution 880 series and Solution 16 when partitioning
 
CP500PW  
Master Partitionable code pad
for viewing status of all areas on Solution 880 series and Solution 16 when partitioned
 
CP105A  
Night Arm Station

Designed for placement by the bedside, the CP105A allows you to arm your system in the STAY mode by pressing one button and also disarm your system provided no alarms have occurred. It also allows you to trigger a panic alarm at any time of the day or night should an emergency situation arise.
 
Solution 880 Ultima Modules
 
 
 
Modem Module
for Solution 844, 880 Ultima and Solution 16 Control panels for SMS reporting, as applicable
 
 
Programming Key
Allows you to store your standard programming options and then
to program other panels with those options in 5 seconds
Enclosures
 
 
Software & Accessories
 
 
 
 

 Solution 880
Solution 880
 
PART NUMBER DESCRIPTION PRICE EX GST
 
CC408X  
Solution 880 Control Panel with transformer

• 8 zone control panel (wired only)
• Not compatible with Bosch DSRF (RF3212E)
• All other features as per the Solution 880 Ultima
 
 
Code Pads
 
CP508LW  
8 Zone LCD Code Pad
 
CP500ALW  
ICON 8 zone addressable code pad
to suit Solution 880 series and Solution 16 when partitioning
CP508W  
8 Zone LED Code Pad
suitable for all Solution 16 panels
CP500AW  
Addressable code pad
to suit Solution 880 series and Solution 16 when partitioning
 
CP500PW  
Master Partitionable code pad
for viewing status of all areas on Solution 880 series and Solution 16 when partitioned
 
CP105A  
Night Arm Station

Designed for placement by the bedside, the CP105A allows you to arm your system in the STAY mode by pressing one button and also disarm your system provided no alarms have occurred. It also allows you to trigger a panic alarm at any time of the day or night should an emergency situation arise.
 
Solution 880 Ultima Modules
 
 
 
Modem Module
for Solution 844, 880 Ultima and Solution 16 Control panels for SMS reporting, as applicable
 
 
Programming Key
Allows you to store your standard programming options and then
to program other panels with those options in 5 seconds
Enclosures
 
 
Software & Accessories
 
 
 
 

 Solution 844
To operate, all it takes is “one touch”. By simply holding the #AWAY key you can arm your system in Away mode. To disarm simply enter your 4 digit code. Code pads can be installed at entry points for your convenience or you can control your system using wireless remotes, which attach to your keyring.

The Solution 844 allows you to choose from either a LED or LCD ICON code pad. Simple ICONS or indicators make it easy to identify the status of your system at all times. The Solution 844 has 4 programmable zones and 4 fixed zones, which can be used to monitor for intrusion, fire, system tamper events or panic buttons. Night Arm Stations can be added to the Solution 844 unit providing added security and protection from the convenience of your bedside. You can arm and disarm the system at the touch of a button and it also has an easy to operate
built in panic function.
 
PART NUMBER DESCRIPTION PRICE EX GST
 
 
Solution 844 Control Panel with transformer

• 8 Zone control panel
• 4 Programmable burglary zones and four 24 hour zones
• 8 User codes
• Dual reporting
• Partitionable to 2 areas
• Domestic dialling
• Selectable EOL
• Automatic arm/disarm
• Day alarm
• Perfect for small to medium residential applications and small retail outlets
• Use with CP508LW or CP508W code pads
 
 
CP508LW  
8 Zone LCD Code Pad
CP105A  
Night Arm Station
 
CP508W  
8 Zone LED Code Pad
 

 G Series
G Series Security Controls
Simpler installation, new personal safety features for specialised applications and Easy Exit make G Series better than ever!

Packed with features, you can easily sell GV2 into environments with special concerns and security needs – such as bank branches, shopping malls, office complexes and schools. Installation is quicker and easier with extra power terminals and ring posts.

Look at these customer-friendly features:

• Two-person disarm – requires two people to disarm using separate codes for high security
• Early ambush – redundant confirmation before and after inspection
• Multiple area access changes – one keypad, one command
• Easy Exit – change arming state with one command
• Access control token – present a token, no keying required

See what we mean? These could be the easiest sell you ever have! And the G Series integrate easily with Bosch CCTV and access control systems so they fit virtually any site.
 
PART NUMBER DESCRIPTION PRICE EX GST
Bosch 9412 Control Panels
 
D9412  
D9412 Security Alarm & Access Control Panel

• Up to 246 fully programmable zones (8 on-board, remainder with expanders, POPIT, or MUX)
• 3 Onboard outputs (D136 reqd for O/P B & C)
• Expandable to 250 users, 8 areas
• 996 Access control cards across 8 doors
• Remote program with RPS
• 1000 event, non-volatile history buffer
D9412G  
D9412 PBC Only
Bosch 9412 Code Pads
 
 
D720  
8 Zone LED Command Centre
to suit Solution 880 series and Solution 16 when partitioning
 
D1255  
16 character VFD Text Command Centre

Command Centres for the D9412 alarm panel. Beige colour to match any decor. D720 for economy, and D1255 for jobs where sunlight strikes directly onto the command centre, or advanced user features are required. Bosch recommend at least 1 D1255 or D1260 command centre per system.
 
D1260  
Advanced LCD Text Command Centre

Command Centre for the D9412 alarm panel. This CC features a 4 line, 20 character, LCD, plain-English codepad. Featuring 8 ATM style ‘soft-keys’, this CC prompts the end user how to operate the system. The less the user needs to remember, the easier the system is to use. Req ROM ver 6.4.
Bosch 9412 Accessories
 
D125b  
12/24v DC Two-Wire Smoke Detector Interface
D136  
D7000-D9000 Series Relay Module
D9210B  
Bosch Single Door Controller in Enclosure
D9210BLC  
Bosch Single Door Controller (PBC only)
D8128D  
OctoPOPIT 8 Point Input Expander
D8129  
OctoRelay 8 Relay Output Expander
D8125  
Popit Interface PCB
D9127U  
Popit Module Single Input (no tamper)
D9127T  
Popit Module Single Input (with tamper)
DS7457i  
MUX Single Input Device
DS7460i  
MUX Dual Input Device
DS7465i  
MUX Input / Output Module
D278S  
2 Wire Popit Smoke Base
Bosch 4412 / 6412 Control Panels
 
D6412  
D6412 Security Alam Panel

• Up to 40 fully programmable or RF zones (8/15 on-board, remainder with expanders)
• Zone doubling
• 4 Onboard outputs (expandable to 20)
• 32 Users, 4 areas
• 3 Different reporting formats, incl pager options
• Programming key capable (PK32)
• Remote program with RPS
• Requires RF3224 for remotes & wireless zones
D6412LC  
D6412 PCB Only
D4412  
D4412 Security Alarm Panel
D4412LC  
D4412 PCB Only
Bosch 4412 / 6412 Code pads
 
D621W  
16 Zone LED Codepad
D623W  
LCD Codepad, 2 Line, 16 Character Display
D625  
VFD Codepad, 2 Line, 16 Character Display
D626  
LCD Codepad, 2 Line, Wih Area Armed Status

Command Centres for the D6412 alarm panel. Beige colour to match any decor. D621 for economy, D623 for most jobs, and D625 for jobs where the sun strikes directly onto the command centre. D626 also indicates the armed status of other areas on the system.
Bosch 4412 / 6412 Accessories
 
DX2010  
8 Zone Input Expander
DX3010  
8 Output Expander
PK32  
D6412 Programming Key
Bosch 4412 / 6412 Wireless Accessories
 
RF3224  
304MHz RF Receiver
RF920  
304MHz Wireless PIR 10m coverage
RF835  
304MHz Wireless PIR Pet Friendly 11m
RF3401  
304MHz Wireless RF Door Reed Switch
RF280THS  
304MHz Wireless RF Smoke Detector
RF3332  
304MHz 2 Button Remote Pendant
RF3334  
304MHz 4 Button Remote Pendant
RF8860M  
304MHz Wireless Panic Button
SE88SHORTBAND  
RF88/SE88 Short Wrist Band
SE88LONGBAND  
RF88/SE88 Long Wrist Band
SE88NECKBAND  
RF88/SE88 Neck Band
SE88WALLMOUNT  
RF88/SE88 Wall Mount Bracket
Bosch 4412 / 6412 / 9412 Programming Accessories
 
DX4010i  
RS232 Interface
LEADNULL  
2m Direct Connect Lead from PC to DX4010
D5360  
D7000-D9000 Series RPS Direct Connect Lead
D5530C  
RPS Bosch Installer Programming Software
D5500CxxxxLTE  
RPS Lite User Kit
 
  Detectors
 Professional Series
These high security motion detectors feature sensor data fusion technology, which enables data comparison from all the detector’s sensors to significantly reduce false alarms. The detectors feature up to five different sensors within each unit as well as a highly sophisticated microprocessor that gathers data from each sensor
and, via a proprietary algorithm, determines whether an alarm is necessary or not. Tri-focus optics technology includes three separate lenses with specific focal lengths for long-range, medium-range and short-range coverage, eliminating the need to adjust the lenses at different mounting heights and providing wall to wall coverage with no gaps.

The two pyroelectric sensors are used for long-range coverage and mid to short-range coverage, respectively, doubling the resolution and signal strength of the detector for improved sensitivity and catch performance, while reducing false alarms.

Professional Series detectors are ideal for a variety of indoor commercial and retail applications such as banks, jewellers and warehouses.
 
PART NUMBER DESCRIPTION PRICE EX GST
 
 
ISC-PPR1-W16  
16m x 21m Professional Series PIR

• User-definable coverage pattern: 16 x 21m or 7.5 x 10m
• Sensor Data Fusion - 4 sensors in one
• TriFocus optical system: improved false alarm memory
• 2 to 3m mounting height
• Adjustable lens and tamper switch
• Active white light suppression
• LED auto dim
• Built-in bubble level
• Alarm memory
• Two piece sliding, locking cover
• Look-down zone
• Hinged chassis and base plate for easy installation
• Remote walk test
 
ISC-PDL1-W18G  
18m x 25m Professional Series Tritech

• User-definable coverage pattern: 18 x 25m or 7.5 x 10m
• Range Adaptive Doppler Microwave
• Sensor Data Fusion - 5 sensors in one
• TriFocus optical system: improved false alarm memory
• 2 to 3m mounting height
• Adjustable lens and tamper switch
• Active white light suppression
• LED auto dim
• Built-in bubble level
• Alarm memory
• Two piece sliding, locking cover
• Look-down zone
• Hinged chassis and base plate for easy installation
• Remote walk test